Vehicle: Suzuki Verona 2005

Owner's Problem Description

The blower fan in my 2005 Suzuki Verona only blows air on the highest setting (number 4), and it makes a loud noise as if it is jammed. Despite the noise, it still blows both hot and cold air. I'm unsure of what to check or what might be causing this issue.

Professional Technical Analysis

The 2005 Suzuki Verona is equipped with a standard HVAC blower motor system, which is critical for cabin air circulation. The vehicle has an estimated mileage of 100,000 miles. The owner's complaint indicates that the blower motor only operates effectively at the highest speed setting, producing a loud noise, suggestive of a mechanical obstruction or motor wear. With the blower fan functioning at all speeds but with noise, the initial suspicion is on the blower motor resistor or the motor itself. The resistor controls the fan speed by varying the voltage supplied to the blower motor. If the resistor is malfunctioning, it can lead to a scenario where the motor receives inadequate voltage at lower settings, causing it to fail to operate correctly. Additionally, a noisy operation could signal failing bearings or other internal components within the blower motor. A thorough electrical and mechanical inspection is essential, focusing on voltage readings at the resistor and motor connections. Normal operation should maintain a voltage range between 12V to 14V at the motor under load. Warning signs include a burning smell, excessive heat, or inconsistent airflow, which could indicate further issues within the HVAC system. Finally, verifying the blower motor's ground connections is critical for ensuring proper function and avoiding intermittent issues.

Possible Causes

Most common causes (ordered by frequency):

  1. Blower Motor Resistor Failure: The resistor regulates the voltage supplied to the blower motor, and if it fails, it can cause improper fan operation at lower speeds. In this case, the blower may only operate correctly at the highest setting, often accompanied by noise due to excessive current draw or a failing motor. - Noise during operation, only functioning at speed 4, voltage readings at lower speeds indicate inadequate power.
  2. Blower Motor Mechanical Failure: The blower motor may have physical wear, such as worn bearings or obstructions within the fan blades, causing the noise and preventing proper airflow. This can lead to increased load on the motor, which can further result in electrical failures. - Loud noise, reduced airflow, visual inspection may show debris in the blower assembly.
  3. Electrical Connection Issues: Corroded or loose connections at the blower motor or resistor can result in fluctuating voltage levels, leading to inconsistent fan operation and potential noise as the motor struggles to operate correctly. - Fluctuating voltage readings, visual inspection may show signs of corrosion or loose connectors.

Diagnostic Steps

Professional Diagnosis Process

Follow these systematic steps to accurately diagnose the issue. Each step builds on the previous one to ensure accurate diagnosis.

  1. STEP 1 - Initial Visual Inspection: Begin with a thorough visual inspection of the blower motor and resistor connections. Look for signs of corrosion, loose wiring, or damaged connectors. Ensuring all connections are tight and clean is crucial for accurate voltage readings.
  2. STEP 2 - Voltage Testing: Using a multimeter, check the voltage at the blower motor connector with the switch in different positions. You should see approximately 12V at the motor when the switch is on. If voltage is low or absent at lower settings, it indicates a resistor issue.
  3. STEP 3 - Blower Motor Function Test: Test the blower motor directly by applying battery voltage to it. If the motor operates normally without noise, the issue is likely with the resistor. If it still makes noise, the blower motor may need to be replaced.
  4. STEP 4 - Inspecting for Mechanical Obstructions: If the blower motor is noisy, remove it and inspect for any debris or obstructions in the fan assembly. Clear any debris found and ensure the fan blades can rotate freely.

Repair Recommendations

CRITICAL PRIORITY - Replace Blower Motor Resistor: If the resistor is confirmed faulty, replace it with an OEM part (P/N 89180-0E010), typically costing around $50-80. After replacement, clear codes and retest the system to ensure proper function.

Priority: Medium

HIGH PRIORITY - Replace Blower Motor: If the blower motor is found to be the issue, replace it with an OEM part (P/N 87103-0E020) at an estimated cost of $150-250. Ensure to inspect the wiring harness for any damage during installation.

Priority: Medium

MEDIUM PRIORITY - Electrical Connection Maintenance: Clean and secure all electrical connections at the blower motor and resistor to prevent future issues. Use dielectric grease to protect against corrosion.

Priority: Medium

Preventive Tips

  • Regular HVAC System Checks: Conduct routine inspections of the HVAC system every six months to identify any early signs of failure. This should include testing blower operation and checking for any unusual noises.
  • Electrical Connection Maintenance: Periodically inspect and clean electrical connections for signs of corrosion or wear, and apply dielectric grease to protect against moisture damage.
  • Monitor Blower Performance: Keep an eye on the blower motor's performance and listen for any unusual noises during operation. If any irregularities are noticed, take action immediately to prevent further damage.

Diagnose Issue

Use GeekOBD APP for professional diagnosis!

  • Real-time data monitoring
  • Advanced diagnostic features
  • Step-by-step repair guidance
  • Professional-grade analysis